Products
Protection of circuits against short-circuit currents, protection of circuits against overload currents switch, isolation.
EBS8B-125 circuit-breakers are used in domestic installation as well as in commercial and industry electrical distribution systems.
Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage.
Tripping curves:
C curve (10In + 20%)
Protection for resistive and inductive loads with low inrushcurrent.
D curve(12In + 20%)
Protection for circuits which supply loads with high inrushcurrent at the circuit losing(LV/LV transformers, breakdown lamps)
| Standard | IEC/EN60898-1, IEC/EN60947-2 | ||
| Rated current In | A | 80, 100, 125 | |
| Rated voltage Ue | V | 230/240V (1P+N), 240/415V (1P), 400/415V (2P/3P/3P+N/4P) | |
| Rated frequency | Hz | 50/60Hz | |
| Poles | P | 1, 2, 3, 4, 1P+N, 3P+N | |
| Mechanical life | 20000 | ||
| Electrical life | 10000 | ||
| Rated short-circuit breaking capacity Icn | A | 10000 | |
| Operating short-circuit breaking capacity Ics | A | 10000 | |
| Rated insulation voltage Ui | V | 500 | |
| Rated impulse withstand voltage(1.2/50)Uimp | kV | 6.2 | |
| Dielectric test voltage | V | 2000 (50Hz, 1 minute) | |
| Vibration resistance(IEC/EN 60068-2-6) | No obvious vibration and impact | ||
| Terminal Blocks | Minimum connectable conductor cross-sectional area (mm²) | 1.5 | |
| Maximum connectable conductor cross-sectional area (mm²) | 50 | ||
| Standard connection torque (N·m) | 3-3.5 | ||
| Maximum withstand torque (N·m) | 3.5 | ||
| Conductor insertion depth (mm) | 10-15 | ||
| Reference Temperature | °C | 30 | |
| Operating Temperature | °C | -25~+40 | |
| Storage Temperature | °C | -35~+85 | |
| Applicable Altitude | m | ≤2000 | |
| Trip Type | Thermal magnetic tripping | ||
| Instantaneous trip type | Type C (10In ± 20%) | · | |
| Type D (12In ± 20%) | · | ||
| Cable Entry | Both up and down | ||
| Installation Method | TH35-7.5 standard guide rail | ||
| Pollution Degree | 2 | ||
| Protection level | Direct installation | IP20 | |
| Install in the distribution box | IP40 | ||

Residential Buildings · Commercial Buildings · Industrial Facilities · Distribution Panels · Lighting Circuits · Power Distribution · Solar PV Systems
Q1: Can I get samples for testing?
Yes. Samples are available for quality and performance testing.
Q2: Do you support OEM/private labeling?
Yes. We support OEM/ODM, including private labeling and customized packaging.
Q3: What certifications are available for this model?
CE, CB, TÜV and other certifications are available depending on the model. Please contact us for details.
Q4: Can you supply different poles and tripping curves?
Yes. Different poles and B/C/D tripping curves are available depending on the model.
Q5: What is the typical production lead time?
Typically around 35 days, depending on order quantity and customization requirements.
![]() |
|||
| Quality Assurance» | View Certifications» | ||